Clever Solutions
Clever Solutions SaaS LLC

Smart Hard Hat Line

In development

Six SKUs of industrial head protection, designed to ANSI/ISEA Z89.1, with a display, sensors and radios studied as add-ons. In development. Not certified, not tested, not for sale, no price.

Why the standard comes first

OSHA 29 CFR 1926.100 (construction) requires employers to provide head protection that meets ANSI Z89.1. The editions written into the rule are Z89.1-1997, -2003 and -2009. This line is being designed to that standard. The hat has to stay a hard hat first; every display, sensor, window and battery is judged by whether it lets the hat still pass for the Type and Class on its label.

OSHA does not certify or approve PPE. A site’s own hazard assessment and PPE program still govern.

The six SKUs

Type is the impact path. Type I is crown impact. Type II adds lateral impact. Class is the electrical claim: Class G is a low-voltage proof test, Class E is a high-voltage proof test, and Class C makes no electrical claim. Each SKU is one Type and one Class.

I-G · Type I, Class G

Crown impact, low-voltage electrical proof.

Design constraint: no holes or conductors through the shell above the test line.

I-E · Type I, Class E

Crown impact, high-voltage electrical proof.

Design constraint: the most restrictive cell for electronics. Nothing conductive may bridge inside to outside.

I-C · Type I, Class C

Crown impact, no electrical claim. Vents allowed.

Design constraint: fewest electrical limits. Not for work near live conductors.

II-G · Type II, Class G

Crown plus lateral impact, low-voltage electrical proof.

Design constraint: side and rear modules sit in the lateral impact zone.

II-E · Type II, Class E

Crown plus lateral impact, high-voltage electrical proof.

Design constraint: the hardest cell. Lateral impact zone and no conductive path.

II-C · Type II, Class C

Crown plus lateral impact, no electrical claim. Vents allowed.

Design constraint: lateral impact and chin-strap retention with added mass. Not for work near live conductors.

A Z89.1 claim is all-or-nothing for the Type and Class marked on the hat.

Electronics under study

These are design targets and candidate parts, not a frozen parts list. No part is selected, no vendor is signed, and no performance figure is claimed.

Micro-OLED HUD
A small monocular display at the brim, out of the main impact shell. No brightness or runtime is claimed.
Thermal, UV and night vision
A thermal camera, a UV sensor and a low-light (night-vision) camera at the front brim and top. Each needs a window, and a window is a shell opening, especially on Class G and E. No detection ranges are claimed.
Multi-gas: CO, H2S, LEL, O2
A four-gas pod kept outside the protective shell. Advisory only: it is not a certified gas detector and does not replace one. Hazardous-location use is not claimed.
Bone-conduction audio
A transducer at the suspension edge so a worker can talk and still hear the site, without reducing suspension clearance. No battery hours are claimed.
Fall and man-down
A motion sensor for possible fall, impact and man-down alerts.
GNSS and NFC
Location attached to an alert, and an NFC tag for pre-use inspection records.
Power
A lithium battery pack. Chemistry, capacity and placement are still open. Runtime is not a claim.

Two ways to build it are being studied side by side: electronics in our own Z89.1 shell, or a clip-on pod on an already-certified host hat. Neither is chosen.

First planned version: SH-B1 Connected Safety Pod

SH-B1 is a clip-on pod for one named Type I Class C host hat family. It is planned for fall, impact and man-down alerts with a buzz and light on the pod and an alert to a crew phone, GNSS location on the alert, and an NFC inspection tag that can be read with a flat battery. No drilling, no adhesive, and no cables through the hat. SH-B1 has no HUD, camera, audio or gas sensing; those belong to the full line above. Class C gives no electrical protection, so SH-B1 is not for work near energized conductors or in hazardous locations. It may not detect every fall and is not a substitute for supervision or emergency services.

Status

  • In development. No prototype, no lab testing, no test report.
  • Not certified to ANSI/ISEA Z89.1 or any other standard. No compliance, intrinsic-safety or gas-detector certification is claimed.
  • Not for sale. No price. No host-maker authorization in hand, and no supplier or partner signed.
  • Nothing would ship until the hat or pod is tested as installed by an accredited lab and battery and radio safety work is done.

Pilot and partner inquiries

If you run crews and want to be considered for a future pilot, or you make shells or components and want to talk, email us. An inquiry is not an order.

Request this — pilot or partner inquiry

An inquiry is not an order, and nothing is charged.